Plasticon

On behalf of United Utilities, KMI commissioned Plasticon Ltd to manufactur and install an odour abatement plant at Burnley wastewater Treatment Works. As part of the contractual requirements, Plasticon were required to demonstrate the equipment’s ability to confirm to the original equipment specifications, as specified by KMI.

Performance Of Test of Odour Assessment

SES was commissioned to complete the odour performance test, which included measurements across the abatement equipment of the following key odour parameters:

  • Odour concentration (ouE/m3)
  • Hydrogen Sulphide
  • Ammonia
  • Dimethyl sulphide
  • Total Mercaptans
  • Total volatile organic compounds
  • Air flows
  • Differential Pressures

Over the course of 28 days, SES were able to fulfil the monitoring requirements and demonstrate that the abatement equipment was performiong to specification. In turn, Plasticon were able to hand over the asser to KMI and complete the project.

 

“SES are proactive, knowledgeable & very helpful. Very constructive working relationship”

– Graham Mansseur (Project manager at Plasticon)

Want expert advice?

Call us now: +44 (0) 1905 362 100

Cookie Control

Cookie control

We have placed cookies on your device to help make this website better.

I'm fine with this

We have placed cookies on your device to help make this website better.

You can use this tool to change your cookie settings. Otherwise, we’ll assume you’re OK to continue.

Some of the cookies we use are essential for the site to work.

We also use some non-essential cookies to collect information for making reports and to help us improve the site. The cookies collect information in an anonymous form.

To control third party cookies, you can also adjust your browser settings.

I'm fine with this
(One cookie will be set to store your preference)
(Ticking this sets a cookie to hide this popup if you then hit close. This will not store any personal information)
Information and Settings Cookie policy