Chapter 5: The Hierarchy of Dust Control
Effective dust management isn’t simply about choosing a piece of equipment. Before deciding how to suppress or capture dust, it is important to consider whether the dust-generating activity, material or process can be eliminated, substituted or controlled at source.
The hierarchy of control provides a structured way to consider different control measures, starting with those that can remove or reduce the hazard before relying on measures that depend more heavily on individual behaviour.
In practice, effective dust management often combines several levels of the hierarchy rather than relying on a single control.
What is the hierarchy of control?
The hierarchy generally follows five levels:
- Elimination – remove the hazard or avoid the hazardous activity.
- Substitution – replace the material, process or activity with a lower-risk alternative.
- Engineering controls – physically control, contain or isolate the hazard.
- Administrative controls – change how work is organised or carried out.
- Personal protective equipment (PPE) – protect individuals from remaining exposure.
The hierarchy is a framework for selecting appropriate controls. The most effective approach will depend on the circumstances, and several controls may need to work together to adequately manage the risk.
1. Elimination
The first question is whether the dust-generating activity can be removed altogether.
Depending on the operation, this could involve changing a process so that cutting, crushing, transferring or handling dusty material is no longer necessary.
Complete elimination isn’t always practical, particularly in industries where handling or processing material is fundamental to the operation. Where it is reasonably practicable, however, removing the activity or hazard can prevent the associated dust exposure from occurring in the first place.
2. Substitution
If the activity can’t be eliminated, it may be possible to replace a material, process or working method with one that generates less dust or presents a lower risk.
This could mean using a different material, changing the form in which a material is supplied, or changing how a task is completed to reduce the amount of airborne dust produced.
Substitution needs to be considered carefully to make sure the alternative does not introduce a different or greater hazard.
3. Engineering controls
Engineering controls physically reduce, contain or capture dust without relying primarily on workers to avoid exposure.
Examples include:
- Dust suppression systems
- Misting and spray systems
- Dust cannons
- Dust extraction
- Local exhaust ventilation (LEV)
- Enclosed processes
- Conveyor covers
- Wind barriers
- Wheel-washing systems
Dust suppression sits at this level of the hierarchy.
Where water-based suppression is appropriate, controlling dust close to its source can help prevent particles from becoming widely dispersed. Other applications may be better suited to extraction, enclosure or a combination of engineering controls.
The advantage of engineering controls is that they can control dust through the design of the process or equipment rather than relying solely on workers to change their behaviour.
4. Administrative controls
Administrative measures change how work is carried out rather than physically removing or containing the dust.
These can include:
- Dust-management plans
- Traffic and access controls
- Scheduling particularly dusty activities
- Staff training
- Regular housekeeping
- Equipment inspection and maintenance
- Monitoring weather and site conditions
Administrative controls can support engineering measures and help ensure they continue to work effectively.
For example, a dust suppression system may be highly effective when correctly positioned and maintained, but operating procedures, inspections and staff training can help ensure it continues to be used correctly.
5. Personal protective equipment
PPE forms the final layer of protection.
Depending on the hazard, this can include respiratory protective equipment, eye protection and protective clothing.
PPE can be important where exposure cannot be adequately prevented through other measures, but it doesn’t stop dust from being generated or spreading around a site. It should therefore form part of a wider control strategy rather than being the first or only response to a dust problem.
PPE also relies on correct selection, fitting, use, maintenance and worker behaviour. For this reason, HSE identifies PPE as the final level in the hierarchy of control.
Where does dust suppression fit?
Dust suppression is an engineering control, but that doesn’t mean it should automatically be the starting point for every site.
A well-designed dust-management strategy might combine process improvements, enclosure, suppression, extraction, housekeeping, monitoring, training and PPE.
For example, a recycling facility could reduce dust generation through its operating procedures, enclose particular processes, use suppression around material handling areas and provide appropriate PPE for remaining exposure.
The most appropriate combination will depend on the source of the dust, the process involved, the working environment and who or what could be affected.
From the Field
Asking “Which dust cannon do we need?” can be the wrong place to start. First identify where the dust comes from, how it behaves and what needs to be controlled. The answer might be a dust cannon, a fixed misting system, an enclosure or a combination of different measures.
Key takeaways
- The hierarchy of control provides a structured approach to selecting measures to eliminate or reduce hazards and exposure.
- Elimination and substitution should be considered before engineering controls where reasonably practicable.
- Dust suppression is one type of engineering control.
- Administrative controls help support physical dust-control measures and keep them working effectively.
- PPE provides an additional layer of protection but doesn’t remove the dust itself.
- Effective dust management often requires several controls working together.